Load Switch Protection IP
Part Number | D008 | D043 | D022 | D045 |
---|---|---|---|---|
FET | Internal | Internal | Internal | BCD |
Ron (typ) (mOhm) | 5.3 | 4.3 | 3.3 | 3 |
Vin (min) (V) | 0.8 | 0.2 | 0.5 | 4.5 |
Vin (max) (V) | 5.5 | 5.5 | 13.5 | 16 |
Vabsmax_cont (V) | - | - | 18 | 24 |
Current limit (min) (A) | - | - | - | 2 |
Current limit (max) (A) | - | - | 40 | 20 |
Imax (A) | 6 | 10 | 17 | 15 |
Overcurrent response | None | None | Circuit breaker | Circuit breaker, Current limiting |
Fault response | None | None | None | Auto-retry, Latch-off |
Soft start | Fixed Rise Time | Fixed Rise Time | Adjustable | Adjustable |
Overvoltage response | - | - | - | Cut-off |
Features | Quick output discharge | Quick output discharge | Power good signal , Short-circuit protection | Current monitoring, Fault output, Power good signal |
Operating temperature range (Celsius) | -40 to 105 | -40 to 105 | -40 to 125 | -40 to 125 |
Shutdown current (ISD) (typ) (uA) | 0.1 | 1.1 | 0.57 | 500 |
Quiescent current (Iq) (typ) (uA) | 0.6 | 12 | 250 | 1000 |
Thermal Shutdown Threshold | 150 | 150 | 150 | 145 |
Device type | Inrush current control | Inrush current control | Load switch | eFuses and hot swap controllers |